UNICUS II - THE TOTAL SYSTEM

    The UNICUS II SCBA Cylinder Recharging Station is the total system for recharging high or low pressure SCBA or booted SCUBA bottles. The integrated system design combines a BAUER four or five stage high pressure compressor, breathing air purification system, air storage system, cascade fill panel and containment fill station into one user friendly work station.

Independently tested for safety, a UL listed electrical panel and the proven reputation for superior performance makes UNICUS II the most advanced fill station available.

5000 PSI / 6000 PSI  STANDARD FEATURES

bulletBAUER Breathing Air Purification System
bulletSECURUS Electronic Monitoring System
bulletThree (3) Fill Hoses Complete with Bleed Valves and SCBA Fill Adapters of Choice
bulletGround Fault Interrupt Electrical Protection
bulletContainment Fill Station with Cylinder Scuff Guard Strips
bulletIlluminated, Polished Stainless Steel Cascade Fill Control Panel
bulletPolished Stainless Steel Gauge Panel Complete with a Gauge for each Stage of Compression, Hourmeter and Oil Pressure Gauge
bulletEmergency Stop Switch
bulletUL Listed Electrical Panel
bulletTwo (2) ASME Code Stamped Cylinders ( *424 scf Each, 4:1 Safety Factor at 5000 PSI   *481 scf Each, 3:1 Safety Factor at 6000 PSI)
bulletPlumbing and Panel Mounted Valves and Gauges to Facilitate the Addition of up to Two (2) Additional Air Storage Cylinders
bulletMagnetic Motor Starter with Overload Protection and Manual Reset
bulletControl Voltage Transformer with Fuse
bulletOn/Off Switch
bulletPower-On Light
bulletFinal Air Pressure Switch (automatic start/stop)
bulletCompressor Low Oil Pressure Shutdown with Fault Light
bulletCompressor High Temperature Shutdown with Fault Light
bulletPressure Maintaining Valve
bulletInlet Filter Maintenance Indicator (panel mounted)
bulletAutomatic Condensate Drain Complete with Combination Separator-Muffler, Drain Solenoid, Timer and Condensate Reservoir with Automatic "Full" Indicator

New Features

bulletLaser Cut Directional Fill Schematic
bulletAutomatic Storage Bypass to Top Off SCBA / SCUBA Directly from Compressor

5000 PSI SERVICE - COMPRESSOR INCLUDES PURIFICATION SYSTEM

MODEL

NUMBER OF   STAGES

CHARGING RATE FAD** HP PURIFICATION SYSTEM AIR PROCESSING CAPABILITY DIMENSIONS L-W-H INCHES NET WEIGHT LBS WITH 2/ASMES
UNII/7-E1/UNII/7-E3 4 7.6 6.3 5.0 P2 Securus 67,000 cu ft 82-36-73 3400
UNII9-E1/UNII/9-E3 4 9.6 8.0 7.5 P2 Securus 67,000 cu ft 82-36-73 3500
UNII/12-E1/UNII/12-E3 4 12.0 10.1 10.0 P5 Securus 150,000 cu ft 82-36-73 3600
UNII/20-E3 4 20.4 17.0 15.0 P5 Securus 150,000 cu ft 82-36-73 3750
UNII/26-E3 4 26.4 22.0 20.0 P10 Securus 230,000 cu ft 82-36-73 3825

6000 PSI SERVICE - COMPRESSOR INCLUDES PURIFICATION SYSTEM

MODEL

NUMBER OF   STAGES

CHARGING RATE FAD** HP PURIFICATION SYSTEM AIR PROCESSING CAPABILITY DIMENSIONS L-W-H INCHES NET WEIGHT LBS WITH 2/ASMES
UNII/8-E1/UNII/8-E3 4 8.4 7.0 7.5 P2 Securus 67,000 cu ft 82-36-73 3500
UNII10-E1/UNII/10-E3 4 10.2 8.5 10.0 P2 Securus 67,000 cu ft 82-36-73 3550
UNII/13-E1/UNII/13-E3 5 13.2 11.0 10.0 P5 Securus 150,000 cu ft 82-36-73 3650
UNII/19-E3 5 19.2 16.0 15.0 P5 Securus 150,000 cu ft 82-36-73 3800
UNII/25-E3 5 25.2 21.0 20.0 P10 Securus 230,000 cu ft 82-36-73 3895

*Based on recharging an 80 cubic foot tank from 500 to 3000 PSIG.

** Compressor capacity referenced to standard inlet conditions.

E1=Single Phase Electric 230, VAC/60 Hz  E3=Three Phase Electric, 230/460 VAC 60/Hz

Other voltage available upon request.

UNII/8 and UNII/10 are equipped with the four stage K14.11 6000 PSI compressor block.

UNII/13,  UNII/19 and UNII/25 units are equipped with the five stage K18.1 6000 PSI compressor block.

25 and 30 horse power models available un request.

Dimensions and weights are approximated and are subject to change.

 

Information Request Form

Select the items that apply, and then let us know how to contact you.

5000 PSI Units (choose one)

Voltage (single or three phase (*) - three phase only (**))

ASME Storage

Each unit comes equipped with two ASME storage vessels. The Unicus II can be equipped with up to 4 ASME vessels.

Optional Equipment

Carbon Monoxide Monitor with calibration kit

Regulated Panel mounted remote fill hose connection

Regulated remote fill hose connection w/50' Hose Reel

6000 PSI UNITS (choose one)

Voltage (single or three phase (*) - three phase only(**))

ASME Storage

Each unit comes equipped with two ASME storage vessels. The Unicus II can be equipped with up to 4 ASME vessels.

Optional Equipment

Carbon Monoxide Monitor with calibration kit

Regulated Panel mounted remote fill hose connection

Regulated remote fill hose connection w/50' Hose Reel

Send product literature
Send company literature
Have a salesperson contact me

Name
Title
Company
Address
E-mail
Phone

 

 

 

Send mail to Safe Air Systems  with questions or comments about this web site.
QUICK LINKS

Home Page


COD Policy
Only Money Orders or Cashier Check
will be accepted for COD Shipments.

We accept credit cards as well as Corporate
and Municipal Purchase Orders.