SafeAir_Logo.tif (49472 bytes)Safe Air Systems, Inc.

 

Purification

Home Page / Links

 

wpe1.jpg (6130 bytes) AF-531-112-F

Air / Inert Gas - Standard Purifiers

Product ID *CF Processing Capacity SCFM Rating
AF-531-109-F 18,000 12
AF-531-110-F 13,000 12
AF-531-111-F 26,000 20
AF-531-112-F 65,000 40
AF-531-113-F 110,000 40
AF-531-114-F 140,000 60
AF-531-115-F 175,000 75
AF-531-116-F 250,000 75
AF-531-117-F 400,000 75
Construction of Cartridge Holder: Aluminum with Black Hard Anodize

Note: Typical processing capacity (cartridge life) is calculated under true-life conditions as gas saturated with water and at 5000 psi / 80 F

Included: Inlet manifold, check valve, relief valves, cartridge change indicator, priority valve, drain valve, petcock vent, pressure gauge, all stainless steel couplers and fasteners, micron particle filter, X-pendable cartridge set, instructional manual, full 1 year warranty on overall equipment and lifetime warranty against corrosion of the cartridge holders.

Specifications: Working pressure 2000-5000 psi, Operating temperature 120 F, Safety Factor 4:1, Cycle life 15,000

High Capacity Purifiers: For those cases where unusually high volumes of gas are being processed - with regard for economy our High Capacity Purifiers could be your most viable solution. They are intended for installation where flow rates are typical yet extended intervals between cartridge changers are desired. Every model is built around some multiple or our "super tower" cartridge holder and accompanying coalescer.

wpe4.jpg (5826 bytes) AF-531-140-F

Air / Inert Gas - High Capacity Purifiers

Product ID *CF Processing Capacity SCFM Ratings
AF-531-140-F 55,000 30
AF-531-142-F 125,000 50
Construction of Cartridge Holder: Aluminum with Black Hard Anodize

Note: Typical processing capacity (cartridge life) is calculated under true-life conditions as gas saturated with water and at 5000 psi / 80 F

Included: Inlet manifold, check valve, relief valves, cartridge change indicator, priority valve, drain valve, petcock vent, pressure gauge, all stainless steel couplers and fasteners, micron particle filter, X-pendable cartridge set, instructional manual, full 1 year warranty on overall equipment and lifetime warranty against corrosion of the cartridge holders.

Specifications: Working pressure 2000-5000 psi, Operating temperature 120 F, Safety Factor 4:1, Cycle life 15,000

wpe7.jpg (3121 bytes) AF-541-103-F

Economy Duplex Purifiers

Product ID * CF Processing Capacity SCFM Rating
AF-541-101-F 3,500 6
AF-541-103-F 18,000 12
AF-541-104-F 6,500 8
Construction of Cartridge Holder: Aluminum with Black Hard Anodize

These models tackle the needs of low usage or low flow rate producer. By condensing the coalescing and adsorption phases into a single tower we are able to serve up a power-packed purifier in a tiny package - without sacrificing ability.

Included: Check valve, relief valves, priority valve, drain valve, pressure gauge, all stainless steel couplers and fasteners, micron particle filter, cartridge set, instructional manual, full 1 year warranty on overall equipment and lifetime warranty against corrosion of the cartridge holders.

Specifications: Working pressure 2000-5000 psi, Operating temperature 120 F, Safety Factor 4:1, Cycle life 15,000

wpe8.jpg (7842 bytes) AF-801-140-E

Air / Inert Gas - High Flow Purifiers

Product ID * CF Processing Capacity SCFM Rating
AF-801-140-E 50,000 80
AF-801-141-E 175,000 80
AF-801-142-E 300,000 125
Construction of Cartridge Holder: Aluminum with Black Hard Anodize

Sized for the higher flow rates demanded by producers of large volumes of air/gas - our High-Flow purifiers will accommodate as much as 125 SCFM with extended periods between cartridge changes. They are stout and rugged - built of some of the strongest materials as exhibited by the main cartridges holders in 4130 grade steel.

Included: Inlet manifold , standard coalescer, check valve, relief valves, cartridge change indicator, high flow priority valve, drain valve, petcock vent,  pressure gauge, all stainless steel couplers and fasteners, micron particle filter, cartridge set, instructional manual, full 1 year warranty on overall equipment and lifetime warranty against corrosion of the cartridge holders.

Specifications: Working pressure 2000-6000 psi, Operating temperature 120 F, Safety Factor 4:1, Cycle life 15,000

Optional: High Capacity Micronic Filter, floor mounted chassis

Send mail to Safe Air Systems  with questions or comments about this web site.
QUICK LINKS

Home Page


COD Policy
Only Money Orders or Cashier Check
will be accepted for COD Shipments.

We accept credit cards as well as Corporate
and Municipal Purchase Orders.