UNICUS II - THE TOTAL SYSTEM

Unicus II Cylinder Recharging Station is the total system for recharging high or low SCBA or SCUBA cylinders. The integrated system design combines a BAUER four or five stage high pressure compressor, BAUER breathing air purification system, air storage system, cascade fill panel and containment fill station into one user friendly workstation. Independently tested for safety, a UL listed electrical assembly and the proven reputation for superior performance makes the Unicus II the most advanced fill station available.

 

UN II/ 26 E3

UN II/ 42 E3

                          

STANDARD FEATURES 5000/ 6000 PSIG

 

5000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT
UN II 10-E1/E3

4

10.2 8.5 7.5 1180

P-2 SECURUS

84x36x77 3400
UN II 13-E1/E3

4

13.3 11.1 10 1420

P-2 SECURUS

84x36x77 3600
UN II 20-E3

4

20.4 17.0 15 1300

P-5 SECURUS

84x36x77 3750
UN II 26-E3 4 26.4 22.0 20 1350

P-5 SECURUS

84x36x77 3825
UN II 42-E3 4 42.0 35.0 30 1300

P-10 SECURUS

102x36/42x77 4500

 

 

6000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT
UN II 10H-E1/E3

4

9.7 8.1 7.5 1180

P-2H SECURUS

84x36x77 3550
UN II 13H-E1/E3

4

13.0 10.8 10.0 1420

P-2H SECURUS

84x36x77 3650
UN II 19H-E3

5

19.2 16.0 15.0 1050

P-5H SECURUS

84x36x77 3800
UN II 25H-E3 5 25.2 21.0 20.0 1300

P-5H SECURUS

84x36x77 3895
UN II 35H-E3 4 35.9 28.9 30.0 1200

P-10H SECURUS

102x36/42x77 4550

 

*Based on recharging an 80 cubic foot tank from 500 to 3000 PSIG.  **Compressor capacity referenced to standard inlet conditions.  + Purification supplied separately for remote mounting.  E3=Three phase electric, 230/ 460 VAC/ 60 Hz. Other voltages available on request. Dimensions and weights are approximate and are subject to change.