OPEN VERTICAL DESIGNS

   5000 / 6000 PSIG  -  ELECTRIC  MOTOR  DRIVE

 

 

STANDARD FEATURES - 5000/ 6000 PSIG 
  • 5 foot SCBA or SCUBA fill assembly (3 stage models)
  • Power-on light.
  • High temperature shutdown switch.  
  • Belt guard designed to meet OSHA guidelines.
  • UL listed electrical assembly.
  • Final pressure switch. 
  • Hourmeter.

OPTIONAL FEATURES - FACTORY  INSTALLED

  • Gauge panel.
  • Automatic condensate drain. 
  • Low oil pressure switch.
  • Fill manifold or CO monitor. 
  • Purification upgrade.
  • Other options available upon request.

 

5000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT

C II V-E1/ E3 3 6.0 5.0 5.0 1250 P-0 29x44x56 610
M II V-E1/ E3 3 8.4 7.0 7.5 1250 P-0 29x44x56 626
K 10 V-E1/ E3 4 10.2 8.5 7.5 1180 P-2 29x44x56 700

 

 

6000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT

H5V-E1/ E3

3

5.0

4.0

5.0

1050

P-2H SECURUS

29x44x56

620

H10V-E1/ E3 4 9.7 8.1 7.5 1180 P-2H SECURUS 29X44X56 720

 

 

 

*Based on recharging an 80 cubic foot tank from 500 to 3000 PSIG.  **Compressor capacity referenced to standard inlet conditions. E1=Single phase electric, 230 VAC/ 60 Hz.   E3=Three phase electric, 230/ 460 VAC/ 60 Hz.  Other voltages available on request. Dimensions and weights are approximate and are subject to change. 

 

STANDARD FEATURES - 5000/ 6000 PSIG 
  • BAUER breathing air purification system.
  • Automatic condensate drain system (K26 thru K60V) 5000 PSI. Standard 6000 PSI.
  • High temperature/ oil pressure shutdown switch with panel mounted light.  
  • Belt guard designed to meet OSHA specifications.
  • UL listed electrical assembly.
  • Hourmeter.
  • SECURUS - K60/ 5000 PSI. Standard 6000 PSI. 

OPTIONAL FEATURES - FACTORY  INSTALLED

  • Automatic condensate drain K13/ K20. 
  • Purification upgrade.
  • Other features available on request.

 

5000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT

K 13V-E1/ E3 4 13.3 11.1 10.0 1420

P-4

35X40X56 700
K 20V-E3 4 20.4 17.0 15.0 1300

P-4

35X40X56 800
K 26 V-E3 4 26.4 22.0 20.0 1350

P-5 

42X40X56 900
K 36 V-E3 4 36.0 30.0 25.0 1000 P-10 42X62X72 1100
K 42 V-E3 4 42.0 35.0 30.0 1300 P-10 42X62X72 1200
K 60 V-E3 4 60.0 50.0 40.0 1350 P-12 SECURUS 42X83X72 2800

 

 

6000 PSI SERVICE

MODEL

STAGES

SCFM*

FAD**

HP

RPM

PURIFICATION

DIMENSIONS

WEIGHT
H13V-E1/ E3

4

13.0

10.8

10.0

1420

P-2H SECURUS

42X40x56

700
H19V-E3 5 19.2 16.0 15.0 1050 P-5H SECURUS 42X40x56 920
H25V-E3 5 25.2 21.0 20.0 1300 P-5H SECURUS 42X40x56 980
H27V-E3 4 27.5 23.0 25.0 1000 P-10H SECURUS 42X62X72 1100
H35V-E3 4 35.9 29.8 30.0 1200 P-10H SECURUS 42X62X72 1300

 

 

*Based on recharging an 80 cubic foot tank from 500 to 3000 PSIG.  **Compressor capacity referenced to standard inlet conditions. E1=Single phase electric, 230 VAC/ 60 Hz.   E3=Three phase electric, 230/ 460 VAC/ 60 Hz.  Other voltages available on request. Dimensions and weights are approximate and are subject to change.